OR-CORD

31 product code

OR-CORD

OR-CORD is a sealing component for controlling lubricant leakage and limiting contamination at the mounting position. Confirm size, material and operating conditions before selection.

Loading product code list…

Detailed technical content

O-Ring cord solves non-standard size requirements

O-Ring cord is a continuously extruded elastomer with a circular cross-section. Users can cut it to the required length and join the two ends to form a ring of the desired diameter, making it particularly useful for large rings, uncommon sizes or urgent situations where a molded O-Ring of the correct size is unavailable.

NQKSF emphasizes that it is a flexible solution for dimensional and lead-time requirements, but not a replacement for every molded O-Ring.

Joint quality is the primary concern

Unlike a one-piece molded O-Ring, a ring made from cord has a joint. Parker notes that the joint is weaker than a precision-molded O-Ring and may be disadvantageous in gas, vacuum, high-pressure or demanding chemical applications. Cut quality, squareness of the two ends, adhesive material or vulcanization method directly affect sealing performance.

Cross-section and material must still meet the groove requirements

The cord can be cut to any circumference, but the cross-sectional diameter cannot be selected arbitrarily. The cross-section must match the groove to provide correct compression, and the material must suit the medium and temperature just as with a conventional O-Ring.

FAQ

Frequently asked questions

Can O-ring cord replace a moulded O-ring in every position?

No. O-ring cord is useful for large or non-standard sizes and quick or temporary repairs, but a joined ring has a splice that a moulded ring does not. For high pressure, gas, vacuum or special reliability requirements, check whether the manufacturer permits a joined ring or requires a dedicated moulded or vulcanized O-ring.

When making a ring from O-ring cord, can the groove circumference simply be measured and cut to that exact length?

One simple formula should not be used for every application. The working diameter, installation stretch and joining method must be considered to determine the correct cut length. Both ends must be cut cleanly and square, then joined accurately to avoid a step or gap.

Is the splice of an O-ring cord assembly the most likely leakage point?

It is a location requiring special control. Parker notes that the splice of a cord-spliced ring can be weaker than a continuous moulded O-ring. If the adhesive is incompatible with the fluid, the ends are misaligned or the joint lacks strength, leakage may begin there before elsewhere on the ring.

Can the same O-ring cord be used for oil, water and chemicals when its cross-section is correct?

No. Cross-section determines geometry, while material determines compatibility with fluid and temperature. The cord compound must be known and selected for the operating conditions. If the material is unknown, do not use it for a critical fluid merely because the diameter is suitable.